Next Article in Journal
Modeling the Groundwater Dynamics of the Celaya Valley Aquifer
Previous Article in Journal
Equilibrium, Kinetic and Thermodynamic Studies for the Adsorption of Metanil Yellow Using Carbonized Pistachio Shell-Magnetic Nanoparticles
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Synthesis of Fumed-Pr-Pi-TCT as a Fluorescent Chemosensor for the Detection of Cyanide Ions in Aqueous Media

by
Sepideh Saberi Afshar
1,
Ghodsi Mohammadi Ziarani
1,*,
Fatemeh Mohajer
1,
Alireza Badiei
2,
Siavash Iravani
3 and
Rajender S. Varma
4,*
1
Department of Organic Chemistry, Faculty of Chemistry, University of Alzahra, Tehran 19938-91176, Iran
2
School of Chemistry, College of Science, University of Tehran, Tehran 14155-6455, Iran
3
Faculty of Pharmacy and Pharmaceutical Sciences, Isfahan University of Medical Sciences, Isfahan 81746-73441, Iran
4
Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute, Palacky University, Šlechtitelů 27, 783 71 Olomouc, Czech Republic
*
Authors to whom correspondence should be addressed.
Water 2022, 14(24), 4137; https://doi.org/10.3390/w14244137
Submission received: 20 November 2022 / Revised: 14 December 2022 / Accepted: 15 December 2022 / Published: 19 December 2022

Abstract

:
In this research, fumed silica scaffolds modified via treatment with (3-chloropropyl)-triethoxysilane, piperazine, and trichlorotriazine groups were deployed for the specific detection of cyanide ions, thus paving the way for the detection of environmental hazards and pollutants with high specificity. Fumed-propyl -piperazine-trichlorotriazine (fumed-Pr-Pi-TCT) was synthesized in three steps starting from fume silica. It was functionalized subsequently using 3-(choloropropyl)-trimethoxysilane, piperazine, and trichlorotriazine, and then, the product was characterized through several methods including Fourier-transform infrared spectroscopy (FTIR) spectrum, thermogravimetric analysis (TGA), and scanning electron microscopy (SEM). Fumed-Pr-Pi-TCT was exposed as a nanoparticle sensor to a range of different anions in aqueous media. This novel sensor could detect cyanide ions as a hazardous material, with the limit of detection being 0.82 × 10−4 M.

1. Introduction

Cyanide (CN) is a multifaceted toxin that can cause poisoning and death in humans [1,2] and is associated with many environmental hazards [2,3,4]. Despite its high toxicity, cyanide has been widely utilized on an industrial scale, which can lead to water pollution [5,6,7]. Recently, chemical sensors have received much attention due to their rapid response, simplicity, sensitivity, and low cost [8,9]. Chemical sensors that operate in conditions without a solvent or the use of an aqueous solvent have found a special place in analytical sensing or diagnostic methods as they follow the principles of green chemistry [10,11,12,13]. On the other hand, photochemistry is a branch of science that deals with the interaction between matter and light [14]. It can be employed in different areas, such as medicine, energy, and environmental sciences [15]. In this context, the construction of nanostructures with unique photochemical properties (light absorption/emission, energy, and electron transfer) via intermolecular interactions has been investigated by researchers [16,17,18,19].
Luminescence silica is broadly employed in many applications, from chemical sensing [20] to interfacial interactions, like immunoassays [21,22,23], bio-analysis [24], nucleic acid studies [25], and drug delivery [26,27,28,29]. These nanoparticles, with intrinsic properties, can be considered promising candidates for designing chemical fluorescence sensors; silica is a transparent material with visible light, which is not tangled in energy- and electron-transfer procedures alone [30]. All fluorescence properties of silica particles are due to the association between organic and inorganic groups on their surface [31,32]. Silica (nano)particles are not inherently toxic; thus, they are environmentally friendly and suitable for in vivo applications [33]. These materials have many active sites on their surface that can be used as scaffolds to react with a variety of organic and inorganic components. Silica scaffolds can protect the entry of foreign chemicals [34,35]. This allows the use of silica particles as chemosensors for the analysis of small dimensions, reducing the possibility of undesired photoreactions [36]. Chemical sensors made from silica (nano)particles have shown the advantages of cost-effectiveness, simplicity, requirement of mild conditions, and ease of separation [37]. Piperazine is a heterocycle with reactive nitrogen groups and was first introduced as an anthelmintic in 1953 [38]. Due to its high reactivity, this compound has been used in many chemical sensors in recent years, as the ensuing material can bind different anions via strong coordination [39,40]. The organic fluorophore moieties bound at the surface of the fumed silicas have become an important research area for selective adsorption and sensing applications [41]. Herein, fumed silica scaffolds, improved by (3-chloropropyl)-triethoxysilane, piperazine, and trichlorotriazine groups, were deployed for the specific detection of cyanide ions. Phenothiazines have notable sensitivity and selectivity for CN among other anions [42]. 5-(4-(Diphenylamine)phenyl) thiophen-2-formaldehyde was synthesized as a turn-on fluorescent reply to CN, which has the advantage of a lower detection limit [43]. In continuation of our previous research, the anion detection ability of the chemosensor among different anions was examined and characterized [18,44]. In this research, the fumed silica surface was modified through treatment with 3-(choloropropyl)-trimethoxysilane, piperazine, and trichlorotriazine, followed by the appropriate structural characterization of the synthesized material; the efficiency of this chemical sensor was demonstrated for the detection of cyanide ion from water.

2. Materials and Methods

2.1. Instruments and Materials

IR spectra were prepared using the FT-IR device TENSOR 27 from the Brooker Company. For thermal gravimetric analysis of the samples, the TGA model Q600, made in America, was used. To acquire scanning electron microscope (SEM) images, a MIRA III FESEM machine made in the Czech Republic was used. PL Spectroscopy model G9800A, from Agilent Company, was used for the investigation and study of the fluorescence spectroscopy of the ensuing material. The chemicals used in this research were purchased from Merck. The raw materials and solvents used in this section include the following: fumed silica, (3-chloropropyl)trimethoxysilane (CPTMS), piperazine, trichlorotriazine (TCT), toluene and methanol as solvents, and metal ions of different anions of Br, NO₃, HSO₃, SO₄², OH, Cl, I, F, CH₃COO, H₂PO₄, CO₃², NO₂, SCN, and CN with a concentration of 0.01 M in distilled water.

2.2. Methods

2.2.1. General Synthesis of Fumed-Pr–Pi-TCT

At first, fumed-Pr–Cl and fumed-Pr–Pi were synthesized as in our reported procedure [45], and then, after activating fumed-Pr–Pi (1 g) at 100 °C, it was refluxed with trichlorotriazine (1 mmol) and dry toluene solvent for 12 h. To obtain the final product (fumed-Pr–Pi-TCT), the resulting precipitate was subjected to a Soxhlet apparatus using methanol as a solvent for 24 h.

2.2.2. Preparation of 10−3 M Aqueous Solution of Fumed-Pr-Pi-TCT in H2O

In volumetric flasks, the aqueous solution of fumed-Pr-Pi-TCT (0.02 g L−1) was prepared in H2O. The aqueous solution of fumed-Pr-Pi-TCT (3 mL) was placed into the sample tubes, and then, an aqueous solution of various anions (200 μL, 10−2 M) was added.

2.2.3. Synthesis of Fumed-Pr-Pi-TCT

In the first step, the surface of fumed silica particles was improved using (3-chloropropyl)-triethoxysilane (ClPTES). In the next steps, it was functionalized with piperazine and trichlorotriazine (TCT), respectively (Scheme 1).

3. Results and Discussion

3.1. Characterization Data

3.1.1. FT-IR Studies

The FT-IR spectra of fumed-Pr-Cl, fumed-Pr-Pi, and fumed-Pr-Pi-TCT are shown in Figure 1. According to the FT-IR spectrum, the organic moieties bonded on the silica fume were proven. The two peaks at 1100 and 800 cm⁻¹ depend on the asymmetric stretching vibrations of Si-O-Si groups. The band was about 3420 cm⁻¹ and can also be considered to be related to the stretching O-H of Si-OH functional groups on the surface. The absorbance bands at 3431 and 1101 cm⁻¹ fit the stretching and bending of N-H in fumed-Pr-Pi, respectively [45]. Finally, the peak at 1700 cm⁻¹ is related to the C=N groups, and the peaks at 1560 to 1400 cm⁻¹ are also related to the aromatic groups in the TCT.

3.1.2. Thermogravimetric Analysis (TGA) Studies

Thermogravimetric analysis (TGA) established the loading of organic compounds on the fumed silica (Figure 2). In the TGA diagram, two weight-loss steps were observed. The first weight loss, which occurred up to 200 °C, is related to the loss of H2O in the fumed silica cavities. Weight loss in the range 200–800 °C is related to the decomposition of existing organic components on the fumed silica. TGA curves indicated, respectively, the weight losses of organic compounds for 8% (fumed-PrCl), 17% (fumed-Pr-Pi), and 45% (Fumed-Pr-Pi-TCT), as predicated for materials with increasing loadings of organic content.

3.1.3. SEM Studies

Fumed silica and Fumed-Pr-Pi-TCT SEM images are shown in Figure 3, which could be used to determine morphology. The image shows that the spherical particle scale of the silica fume had not changed much after functionalization.

3.2. Fluorescence Response of Fumed-Pr–Pi-TCT for CNˉ

To investigate the fluorescence properties of fumed-Pr-Pi-TCT, its solution (0.02 g L−1) was made in an aqueous solvent. Then, its fluorescence response was studied using different anions, such as Br, NO₃, HSO₃, SO₄², OH, Cl, I, F, CH₃COO, H₂PO₄, CO₃², NO₂, SCN, and CN. By adding a 10−2 M concentration of different anions to 3 mL of fumed solution(0.2 g L−1), the spectra were recorded after 30 s. The fluorescence intensity of fumed-Pr–Pi-TCT decreased significantly after the addition of CN but did not change significantly compared to that with other anions, which affirmed that this ligand could be applicable to detect CN among other anions (Figure 4).

3.2.1. Selectivity Studies

To evaluate the selectivity, a CN competition test was performed against other anions. For this purpose, the spectra were recorded by adding anions (100 µL × 10⁻² M) to the mixture of fumed-Pr-Pi-TCT (3 mL H₂O suspension, 0.2 g L⁻¹) and CN⁻ (100 µL × 10⁻² M). The results presented in Figure 5 demonstrate that the CN anion has high selectivity against other anions according to the fluorescence intensity.

3.2.2. Titration Studies

To evaluate the detection potential of this chemical sensor, a titration test was performed. For this purpose, diverse concentrations of CN (1× 10⁻⁴ M to 100 × 10⁻⁴ M) were added to fumed-Pr-Pi-TCT. After each addition, the fluorescence spectrum was recorded. It gradually decreased after adding different amounts of anion (Figure 6).
According to the titration diagram, the fluorescence intensity was reduced by adding CN. By plotting the ratio of fluorescence intensity to different CN concentrations (Figure 7), a linear relationship could be established between them that followed the equation y = −0.0069x + 0.8262, with a regression coefficient of R² = 0.9541. The DL = 3 Sd/m equation was used to calculate the detection limit (DL is the detection limit, Sd is the standard derivation of the blank, and m is the slope of fluorescence intensity) [46]. According to the above equation, the detection limit was obtained 0.82 × 10−4 M.

3.2.3. Competition Studies

To compare our work with other previous research documented in the literature, in terms of the limit of detection (LOD), media with different structures are shown in Table 1. In recent years, the use of fumed silica as a scaffold for the production of organic–inorganic hybrids has garnered special attention due to its simple reactions, non-toxicity, and inexpensive nature, and hence, fumed silica was used in this research.

4. Conclusions

Fumed-Pr-Pi-TCT was prepared successfully via functionalization with piperazine, and the trichlorotriazine and the ensued chemical sensor could selectively and successfully detect CN. The fluorescence intensity was significantly reduced after adding CN in the presence of different anions. In the field of environmental hazards and pollutants, cyanide is one of the most important pollutants in water, soil, and air, which has detrimental ecological impacts on the ecosystem and the environment; thus, its removal from the environment is vital. Fumed-Pr-Pi-TCT can be modified with different nucleophilic groups to yield other newer optical sensors, which could serve as scavengers of metal ions and assorted anions. Therefore, these types of compounds could be used for detecting pollutants successfully.

Author Contributions

S.S.A.: Writing-Original Draft, performing experimental works; G.M.Z., Supervision, Project administration, Editing; F.M., Validation-Supporting, editing Data Analysis, Graphical Abstract Design; A.B., Data Analysis, Editing of the article; S.I., Writing, Review & Editing; R.S.V., Review & Editing. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Ishii, A.; Seno, H.; Watanabe-Suzuki, K.; Suzuki, O.; Kumazawa, T. Determination of cyanide in whole blood by capillary gas chromatography with cryogenic oven trapping. Anal. Chem. 1998, 70, 4873–4876. [Google Scholar] [CrossRef] [PubMed]
  2. Nelson, L. Acute cyanide toxicity: Mechanisms and manifestations. J. Emerg. Nurs. 2006, 32, S8–S11. [Google Scholar] [CrossRef] [PubMed]
  3. Borron, S.W. Recognition and treatment of acute cyanide poisoning. J. Emerg. Nurs. 2006, 32, S12–S18. [Google Scholar] [CrossRef] [PubMed]
  4. Wang, Z.; Zhang, D.; Xiao, X.; Su, C.; Li, Z.; Xue, J.; Hu, N.; Peng, P.; Liao, L.; Wang, H. A highly sensitive and selective sensor for trace uranyl (VI) ion based on a graphene-coated carbon paste electrode modified with ion imprinted polymer. Microchem. J. 2020, 155, 104767. [Google Scholar] [CrossRef]
  5. Bai, C.-B.; Zhang, J.; Qiao, R.; Zhang, Q.-Y.; Mei, M.-Y.; Chen, M.-Y.; Wei, B.; Wang, C.; Qu, C.-Q. Reversible and Selective Turn-on Fluorescent and Naked-Eye Colorimetric Sensor to Detect Cyanide in Tap Water, Food Samples, and Living Systems. Ind. Eng. Chem. Res. 2020, 59, 8125–8135. [Google Scholar] [CrossRef]
  6. László, F. Lessons learned from the cyanide and heavy metal accidental water pollution in the Tisa River basin in the year 2000. In JSTOR; Springer: Berlin/Heidelberg, Germany, 2006; pp. 43–50. [Google Scholar]
  7. Vasudevan, S.; Oturan, M.A. Electrochemistry: As cause and cure in water pollution. Environ. Chem. Lett. 2014, 12, 97–108. [Google Scholar] [CrossRef]
  8. Zhou, J.; Liu, Y.; Tang, J.; Tang, W. Surface ligands engineering of semiconductor quantum dots for chemosensory and biological applications. Mater. Today Commun. 2017, 20, 360–376. [Google Scholar] [CrossRef]
  9. Yung, K.Y.; Schadock-Hewitt, A.J.; Hunter, N.P.; Bright, F.V.; Baker, G.A. ‘Liquid litmus’: Chemosensory pH-responsive photonic ionic liquids. Commun. Chem. 2011, 47, 4775–4777. [Google Scholar] [CrossRef]
  10. Karimi, M.; Badiei, A.; Mohammadi Ziarani, G. A single hybrid optical sensor based on nanoporous silica type SBA-15 for detection of Pb 2+ and I− in aqueous media. RSC Adv. 2015, 5, 36530–36539. [Google Scholar] [CrossRef]
  11. Arumugam, N.; Kim, J. Synthesis of carbon quantum dots from Broccoli and their ability to detect silver ions. Mater. Lett. 2018, 219, 37–40. [Google Scholar] [CrossRef]
  12. Wei, T.-B.; Li, W.-T.; Li, Q.; Su, J.-X.; Qu, W.-J.; Lin, Q.; Yao, H.; Zhang, Y.-M. A turn-on fluorescent chemosensor selectively detects cyanide in pure water and food sample. Tetrahedron Lett. 2016, 57, 2767–2771. [Google Scholar] [CrossRef]
  13. Zhang, D.; Wang, Z.; Yang, J.; Yi, L.; Liao, L.; Xiao, X. Development of a method for the detection of Cu2+ in the environment and live cells using a synthesized spider web-like fluorescent probe. Biosens. Bioelectron. 2021, 182, 113174. [Google Scholar] [CrossRef] [PubMed]
  14. Turro, N.J. Modern Molecular Photochemistry; University science books: Sausalito, CA, USA, 1991. [Google Scholar]
  15. Prodi, L.; Montalti, M.; Zaccheroni, N. Luminescence Applied in Sensor Science; Springer: Berlin/Heidelberg, Germany, 2011. [Google Scholar]
  16. Bonacchi, S.; Genovese, D.; Juris, R.; Marzocchi, E.; Montalti, M.; Prodi, L.; Rampazzo, E.; Zaccheroni, N. Energy transfer in silica nanoparticles: An essential tool for the amplification of the fluorescence signal. In Reviews in Fluorescence 2008; Springer: Berlin/Heidelberg, Germany, 2010; pp. 119–137. [Google Scholar]
  17. Hajiaghababaei, L.; Mardvar, A.; Allahgholi Ghasri, M.R.; Dehghan Abkenar, S.; Badiei, A.; Ganjali, M.; Mohammadi Ziarani, G. Simultaneous Removal of Pb2+ and Cu2+ by SBA-15/di-urea as a Nano Adsorbent. Iran. J. Chem. Chem. Eng. 2022, 41, 163–173. [Google Scholar]
  18. Mohammadi Ziarani, G.; Moradi, R.; Mohajer, F.; Badiei, A. Synthesis of SBA-Pr-NHC as a selective fluorescent sensor for the detection of Ag+ ion in aqueous media. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2022, 267, 120580. [Google Scholar] [CrossRef] [PubMed]
  19. Jamasbi, N.; Mohammadi Ziarani, G.; Mohajer, F.; Badiei, A. A new Hg2+ colorimetric chemosensor: The synthesis of chromeno[d]pyrimidine-2,5-dione/thione derivatives using Fe3O4@SiO2@(BuSO3H)3. Res. Chem. Intermed. 2022, 48, 899–909. [Google Scholar] [CrossRef]
  20. Mohammadi Ziarani, G.; Khademi, M.; Mohajer, F.; Badiei, A. The application of modified SBA-15 as a chemosensor. Curr. Nanomater. 2021, 7, 4–24. [Google Scholar] [CrossRef]
  21. Murray, K.; Cao, Y.-C.; Ali, S.; Hanley, Q. Lanthanide doped silica nanoparticles applied to multiplexed immunoassays. Analyst 2010, 135, 2132–2138. [Google Scholar] [CrossRef]
  22. Liu, W.; Ma, C.; Yang, H.; Zhang, Y.; Yan, M.; Ge, S.; Yu, J.; Song, X. Electrochemiluminescence immunoassay using a paper electrode incorporating porous silver and modified with mesoporous silica nanoparticles functionalized with blue-luminescent carbon dots. Microchim. Acta 2014, 181, 1415–1422. [Google Scholar] [CrossRef]
  23. Di Fusco, M.; Quintavalla, A.; Lombardo, M.; Guardigli, M.; Mirasoli, M.; Trombini, C.; Roda, A. Organically modified silica nanoparticles doped with new acridine-1, 2-dioxetane analogues as thermochemiluminescence reagentless labels for ultrasensitive immunoassays. Anal. Bioanal. Chem. 2015, 407, 1567–1576. [Google Scholar] [CrossRef]
  24. Wang, Z.; Zong, S.; Chen, H.; Wu, H.; Cui, Y. Silica coated gold nanoaggregates prepared by reverse microemulsion method: Dual mode probes for multiplex immunoassay using SERS and fluorescence. Talanta 2011, 86, 170–177. [Google Scholar] [CrossRef]
  25. Moon, J.H.; McDaniel, W.; Hancock, L.F. Facile fabrication of poly (p-phenylene ethynylene)/colloidal silica composite for nucleic acid detection. J. Colloid Interface Sci. 2006, 300, 117–122. [Google Scholar] [CrossRef] [PubMed]
  26. Yang, P.; Quan, Z.; Lu, L.; Huang, S.; Lin, J. Luminescence functionalization of mesoporous silica with different morphologies and applications as drug delivery systems. Biomaterials 2008, 29, 692–702. [Google Scholar] [CrossRef] [PubMed]
  27. Yang, P.; Gai, S.; Lin, J. Functionalized mesoporous silica materials for controlled drug delivery. Chem. Soc. Rev. 2012, 41, 3679–3698. [Google Scholar] [CrossRef] [PubMed]
  28. Hou, Z.; Li, C.; Ma, P.; Li, G.; Cheng, Z.; Peng, C.; Yang, D.; Yang, P.; Lin, J. Electrospinning Preparation and Drug-Delivery Properties of an Up-conversion Luminescent Porous NaYF4: Yb3+, Er3+@ Silica Fiber Nanocomposite. Adv. Funct. Mater. 2011, 21, 2356–2365. [Google Scholar] [CrossRef]
  29. Su, C.; Li, Z.; Zhang, D.; Wang, Z.; Zhou, X.; Liao, L.; Xiao, X. A highly sensitive sensor based on a computer-designed magnetic molecularly imprinted membrane for the determination of acetaminophen. Biosens. Bioelectron. 2020, 148, 111819. [Google Scholar] [CrossRef]
  30. Ow, H.; Larson, D.R.; Srivastava, M.; Baird, B.A.; Webb, W.W.; Wiesner, U. Bright and stable core− shell fluorescent silica nanoparticles. Nano Lett. 2005, 5, 113–117. [Google Scholar] [CrossRef]
  31. Karimi, M.; Badiei, A.; Mohammadi Ziarani, G. Fluorescence-enhanced optical sensor for detection of Al3+ in water based on functionalised nanoporous silica type SBA-15. Chem. Pap. 2016, 70, 1431–1438. [Google Scholar] [CrossRef]
  32. Ahmadi, T.; Bahar, S.; Mohammadi Ziarani, G.; Badiei, A. Formation of functionalized silica-based nanoparticles and their application for extraction and determination of Hg (II) ion in fish samples. Food Chem. 2019, 300, 125180. [Google Scholar] [CrossRef]
  33. Jin, Y.; Kannan, S.; Wu, M.; Zhao, J.X. Toxicity of Luminescent Silica Nanoparticles to Living Cells. Chem. Res. Toxicol. 2007, 20, 1126–1133. [Google Scholar] [CrossRef]
  34. Zu, G.; Shen, J.; Wang, W.; Zou, L.; Lian, Y.; Zhang, Z.; Interfaces. Silica–titania composite aerogel photocatalysts by chemical liquid deposition of titania onto nanoporous silica scaffolds. ACS Appl. Mater. Interfaces 2015, 7, 5400–5409. [Google Scholar] [CrossRef]
  35. Carn, F.; Colin, A.; Achard, M.F.; Deleuze, H.; Saadi, Z.; Backov, R. Rational design of macrocellular silica scaffolds obtained by a tunable sol–gel foaming process. J. Adv. Mater. 2004, 16, 140–144. [Google Scholar] [CrossRef]
  36. Shin, J.H.; Schoenfisch, M.H. Inorganic/organic hybrid silica nanoparticles as a nitric oxide delivery scaffold. Chem. Mater. 2008, 20, 239–249. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  37. Burns, A.; Sengupta, P.; Zedayko, T.; Baird, B.; Wiesner, U. Core/shell fluorescent silica nanoparticles for chemical sensing: Towards single-particle laboratories. Nanomicro. Lett. 2006, 2, 723–726. [Google Scholar] [CrossRef] [PubMed]
  38. Jalageri, M.D.; Nagaraja, A.; Puttaiahgowda, Y.M. Piperazine based antimicrobial polymers: A review. RSC Adv. 2021, 11, 15213–15230. [Google Scholar] [CrossRef] [PubMed]
  39. Das, P.; Rajput, S.S.; Das, M.; Laha, S.; Choudhuri, I.; Bhattacharyya, N.; Das, A.; Samanta, B.C.; Alam, M.M.; Maity, T. Easy, selective and colorimetric detection of Zn (II), Cu (II), F− ions by a new piperazine based Schiff base chemosensor along with molecular logic gate formation and live cell images study. J. Photochem. Photobiol. 2022, 427, 113817. [Google Scholar] [CrossRef]
  40. Goswami, S.; Maity, S.; Maity, A.C.; Das, A.K.; Khanra, K.; Mandal, T.K.; Bhattacharyya, N. A macrocyclic piperazine linked extremely Zn2+ selective fluorescent chemosensor with bio-imaging and for H2PO4− sensing. Tetrahedron Lett. 2014, 55, 5993–5997. [Google Scholar] [CrossRef]
  41. Melde, B.J.; Johnson, B.J. Mesoporous materials in sensing: Morphology and functionality at the meso-interface. Anal. Bioanal. Chem. 2010, 398, 1565–1573. [Google Scholar] [CrossRef]
  42. Martín Várguez, P.E.; Raimundo, J.-M. Naked-Eye Chromogenic Test Strip for Cyanide Sensing Based on Novel Phenothiazine Push– Pull Derivatives. Biosensors 2022, 12, 407. [Google Scholar]
  43. Shi, Q.; Wu, S.T.; Shen, L.; Zhou, T.; Xu, H.; Wang, Z.Y.; Yang, X.J.; Huang, Y.L.; Zhang, Q.L. A Turn-On Fluorescent Chemosensor for Cyanide Ion Detection in Real Water Samples. Front. Chem. 2022, 10, 923149. [Google Scholar] [CrossRef]
  44. Mousavi, Z.; Ghasemi, J.B.; Mohammadi Ziarani, G.; Saidi, M.; Badiei, A. Dihydropyrano quinoline derivatives functionalized nanoporous silica as novel fluorescence sensor for Fe3+ in aqueous solutions(aq). J. Mol. Struct. 2022, 1265, 133408. [Google Scholar] [CrossRef]
  45. Gholamzadeh, P.; Mohammadi Ziarani, G.; Zandi, F.; Abolhasani Soorki, A.; Badiei, A.; Yazdian, F. Modification of fumed silica surface with different sulfonamides via a postsynthesis method and their application as antibacterial agents. Comptes Rendus Chim. 2017, 20, 833–840. [Google Scholar] [CrossRef]
  46. Afshani, J.; Badiei, A.; Lashgari, N.; Mohammadi Ziarani, G. A simple nanoporous silica-based dual mode optical sensor for detection of multiple analytes (Fe3+, Al3+ and CN−) in water mimicking XOR logic gate. RSC Adv. 2016, 6, 5957–5964. [Google Scholar] [CrossRef]
  47. Karimi, M.; Badiei, A.; Mohammadi Ziarani, G. A click-derived dual organic-inorganic hybrid optical sensor based on SBA-15 for selective recognition of Zn2+ and CN− in water. Inorg. Chim. Acta 2016, 450, 346–352. [Google Scholar] [CrossRef]
Scheme 1. Preparative process for fumed-Pr-Pi-TCT chemosensor.
Scheme 1. Preparative process for fumed-Pr-Pi-TCT chemosensor.
Water 14 04137 sch001
Figure 1. FT-IR analysis of (a) fumed-Pr-Cl, (b) fumed-Pr-Pi, and (c) fumed-Pr-Pi-TCT.
Figure 1. FT-IR analysis of (a) fumed-Pr-Cl, (b) fumed-Pr-Pi, and (c) fumed-Pr-Pi-TCT.
Water 14 04137 g001
Figure 2. TGA curves of fumed-Pr-Cl, fumed-Pr-Pi, and fumed-Pr-Pi-TCT.
Figure 2. TGA curves of fumed-Pr-Cl, fumed-Pr-Pi, and fumed-Pr-Pi-TCT.
Water 14 04137 g002
Figure 3. SEM images of (a) fumed silica and (b) fumed-Pr-Pi-TCT.
Figure 3. SEM images of (a) fumed silica and (b) fumed-Pr-Pi-TCT.
Water 14 04137 g003
Figure 4. Fluorescence spectra of the aqueous suspended fumed-Pr–Pi-TCT (3 mL H₂O suspension, 0.2 g L−1) using different anions.
Figure 4. Fluorescence spectra of the aqueous suspended fumed-Pr–Pi-TCT (3 mL H₂O suspension, 0.2 g L−1) using different anions.
Water 14 04137 g004
Figure 5. Selectivity of fumed-Pr–Pi-TCT (3 mL H₂O suspension, 0.2 g L−1) for CN⁻ (100 μL, 1 × 10⁻² M) with equal amounts of interfering anions (λem = 500 nm, λex = 350 nm).
Figure 5. Selectivity of fumed-Pr–Pi-TCT (3 mL H₂O suspension, 0.2 g L−1) for CN⁻ (100 μL, 1 × 10⁻² M) with equal amounts of interfering anions (λem = 500 nm, λex = 350 nm).
Water 14 04137 g005
Figure 6. Fluorescence response of fumed-Pr-Pi-TCT (3 mL H₂O suspension, 0.2 g L−1) after adding different concentrations of CN.
Figure 6. Fluorescence response of fumed-Pr-Pi-TCT (3 mL H₂O suspension, 0.2 g L−1) after adding different concentrations of CN.
Water 14 04137 g006
Figure 7. Stern–Volmer plot for the titration of fumed-Pr-Pi-TCT with different concentrations of CN.
Figure 7. Stern–Volmer plot for the titration of fumed-Pr-Pi-TCT with different concentrations of CN.
Water 14 04137 g007
Table 1. Comparison between various sensors.
Table 1. Comparison between various sensors.
SensorsSolvent SystemSensing IonsLODReference
SSA1H2OCN-2 × 10−4 M[46]
SBA-IIH2OCN-3.9 × 10−4 M[47]
Fumed-Pr-Pi-TCTH2OCN-0.82 × 10−4Present work
1 SBA-15, (3-aminopropyl)triethoxysilane, salicylaldehyde; 2 SBA15, NaN3, 1, 2, 3-triazole linked 8-hydroxyquinoline
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Afshar, S.S.; Ziarani, G.M.; Mohajer, F.; Badiei, A.; Iravani, S.; Varma, R.S. Synthesis of Fumed-Pr-Pi-TCT as a Fluorescent Chemosensor for the Detection of Cyanide Ions in Aqueous Media. Water 2022, 14, 4137. https://doi.org/10.3390/w14244137

AMA Style

Afshar SS, Ziarani GM, Mohajer F, Badiei A, Iravani S, Varma RS. Synthesis of Fumed-Pr-Pi-TCT as a Fluorescent Chemosensor for the Detection of Cyanide Ions in Aqueous Media. Water. 2022; 14(24):4137. https://doi.org/10.3390/w14244137

Chicago/Turabian Style

Afshar, Sepideh Saberi, Ghodsi Mohammadi Ziarani, Fatemeh Mohajer, Alireza Badiei, Siavash Iravani, and Rajender S. Varma. 2022. "Synthesis of Fumed-Pr-Pi-TCT as a Fluorescent Chemosensor for the Detection of Cyanide Ions in Aqueous Media" Water 14, no. 24: 4137. https://doi.org/10.3390/w14244137

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop